High Quality CE Plastic Insulated Control Cable
Using twisted multiple strand bare copper wire or tin plated copper wire as conductor.
PVC Insulated.;
PVC Jacket;
300/500V Rated Voltage Uo/U;
Keeping working temperature under 70C for Long-range operation.
Specifications
1. Flame ratardant cable is difficult to to catch fire
2. Good electric propertity and mechanical stability.
3 OEM is provided.
Copper core PVC insulated PVC sheathed control cable with flame-retardant
I Feature
1 standard: ISO-9001
2 No of cores: 2~37
3 nominal cross- section: 0.75~10 mm2
4 conductor: Copper
II Production standard
The product is manufactured according to GB9330-88, IEC, or other standard as requried by user.
III Structure Diagram of Control cable
IV Application
(1)Flame retardant cable should not only follow the above standard, but also, it's flame retardant besides its fire resistant performance should be devided into 3 types of A/B/C and 4 grades of I /II / III/ IV as perscribed in GA306.1-2001 standard. The A type is the best performance. User can choose it according to its applied plcaes and requirement.
(2)Rated voltage Uo/U is 450/750v
(3)Permissible continuous working temperature of the cable conductor is 70 ° C
(4) Ambient temperature is not lower than 0 ° C and it's minium bending 1 radius is as follows when cable is installed for non-armored cable -not less than 6 times O>D
For armored or copper tase shielded cable not less than 12 times
For shielded flexible cable not less than 6 times O>D
Specification mm 2 |
O.D of Product mm |
Reference weight of cable kg/km |
Minimum insulation resistance at 70°C
(MΩ.km) |
Max D.C resistance at20°C (Ω/km) |
lower limit mm |
upper limit mm |
2×0.75 |
6.7 |
8.1 |
59 |
0.012 |
24.5 |
2×1.0 |
7.0 |
8.5 |
67 |
0.011 |
18.1 |
2×1.5 |
7.9 |
9.5 |
86 |
0.011 |
12.1 |
2×2.5 |
9.0 |
10.9 |
120 |
0.010 |
7.41 |
2×4 |
9.9 |
11.9 |
167 |
0.0085 |
4.61 |
2×6 |
10.8 |
13.1 |
220 |
0.0070 |
3.08 |
3×0.75 |
7.1 |
8.5 |
71 |
0.012 |
24.5 |
3×1.0 |
7.4 |
8.9 |
82 |
0.011 |
18.1 |
3×1.5 |
8.3 |
10.0 |
108 |
0.011 |
12.1 |
3×2.5 |
9.5 |
11.5 |
154 |
0.010 |
7.41 |
3×4 |
10.5 |
12.7 |
210 |
0.0085 |
4.61 |
3×6 |
11.5 |
13.9 |
310 |
0.0070 |
3.08 |
4×0.75 |
7.6 |
9.2 |
846 |
0.012 |
24.5 |
4×1.0 |
7.9 |
9.6 |
100 |
0.011 |
18.1 |
4×1.5 |
9.0 |
10.9 |
132 |
0.011 |
12.1 |
4×2.5 |
10.4 |
12.5 |
193 |
0.010 |
7.41 |
4×4 |
11.4 |
13.8 |
315 |
0.0085 |
4.61 |
4×6 |
13.2 |
15.9 |
413 |
0.0070 |
3.08 |
5×0.75 |
8.2 |
9.9 |
99 |
0.012 |
24.5 |
5×1.0 |
8.6 |
10.3 |
116 |
0.011 |
18.1 |
5×1.5 |
9.7 |
11.7 |
154 |
0.011 |
12.1 |
5×2.5 |
11.3 |
13.6 |
243 |
0.010 |
7.41 |
5×4 |
13.0 |
15.7 |
383 |
0.0085 |
4.61 |
5×6 |
14.3 |
17.3 |
505 |
0.0070 |
3.08 |
V
Production Range
Type |
Name |
Application |
Nominalcross-section(mm 2 ) |
Number of
cores |
KVV |
Copper core PVC insulated PVC sheathed control cable
|
For laying indoors, in cable trench, pipe fixed occasions |
0.75 - 10 |
2 - 37 |
KVVP |
Copper core PVC insulated PVC sheathed braiding shielding control cable |
For laying indoors, in cable trench, pipeline and other fixed shielding places |
0.75 - 10 |
2 - 37 |
KVV 22 |
Copper core PVC insulated steel tape armored PVC sheathed control cable |
For fixed places bearing large mechanical forces and For laying indoors, in cable trench, pipeline |
0.75 - 10 |
2 - 37 |
KVVR |
Copper core PVC insulated and PVC sheathed control soft cable |
For laying indoors in soft places mobile |
0.75 - 10 |
2 - 37 |
KVVRP |
Copper core PVC insulated PVC sheathed braiding shielding control soft cable |
For laying indoors mobile with soft and shielding occasion |
0.75 - 10 |
2 - 37 |
KVVP 2 |
Copper core PVC insulated PVC sheathed copper tape shielding control cable |
For laying indoors, in cable trench, pipeline and other fixed shielding places |
0.75 - 10 |
2 - 37 |
KVVP 2-22 |
Copper core PVC insulated PVC sheathed copper tape shielding steel tape armored control cable |
For laying indoors, in cable trench, pipeline and other fixed shielding places |
0.75 - 10 |
2 - 37 |